Specimen Logistics Transmission System

/

Product Details

Product Description

The specimen logistics transmission system utilizes air suspension technology to automatically transfer specimens through a sealed dedicated pipeline, quickly and efficiently delivering nucleic acid and blood specimens from the collection site to the laboratory. Setting up a fast and dedicated sealed pipeline for specimen transfer in existing fever clinics and laboratories is the most efficient method, significantly reducing the total transfer time (totat) of specimens throughout the process, with no breakpoints and no impact on specimen quality


Product Features

Transmission speed

The system adopts positive pressure suspension transmission technology, which can meet the demand for large sample volume transmission. It can transmit up to 600 meters per minute (7-10m/s) and 1000 samples per hour

 

System protection

The system uses compressed air as the transmission power source, and the compressed air enters the transmission pipeline after being treated with multiple layers of filtration such as dehydration and dehumidification.

Design a ups backup power supply system to ensure the safe and error free delivery of running specimens to the target station during power outages when the device malfunctions, it can be quickly resolved through remote control

 

Type and function of sending station

The ha2518c blood sample sending station, designed specifically for hospital blood collection centers, can achieve batch continuous sending of nucleic acid and blood collection stations, saving operators' machine time and realizing intelligent sending.

 

System piping and installation schedule

The pipeline is made of polyethylene material with an outer diameter of 25-32mm and good ductility, which is convenient for installation and construction.

. Capable of transporting test tubes with a diameter of 12-21 millimeters and a length of 80-126 millimeters (including lids) in pipelines. Easy to install, with a construction period of 2-4 weeks to complete the installation, without affecting the original building layout and normal operation of the hospital

 

Equipment control and accuracy

The system adopts automatic verification technology, high accuracy, strong transmission reliability, and no cross points in transmission mode.

. The sample has no lag or loss, and the interface is rich. It can be directly connected to sorting machines, automated assembly lines and other supporting equipment. It has been proven by users that high-speed transmission has no quality impact on nucleic acid and blood samples it can provide emergency, rapid, and safe solutions for fever clinics, general clinics, emergency departments, inpatient departments, special needs clinics, and high-level wards. The transmission distance can reach over 480m. The total process time (totat)

 

Equipment operation and training

Easy to operate, easy to maintain, low failure rate, automatic transmission of nucleic acid and blood samples after placing them in the sending station, easy to train and start work without the need for professionals, regular disinfection and cleaning (100000 blood samples or half a year: nucleic acid samples are laid in dual pipelines, and can be disinfected with ozone or disinfectant according to hospital needs), and simple maintenance procedures

 


Application Areas